Failure Modes Reference for Bimetallic Conductors

A reference table of common failure modes in CCA, CCS, NCC, SCC and composite PV ribbon, with root causes, detection methods and prevention.

Audience
Quality engineers, reliability engineers, supplier quality engineers
Purpose
Give engineers a single-page reference to identify failure modes quickly during sample validation and field returns.

Bond and interface failures

Failures at the cladding interface. Most critical — usually means the supplier used electroplating or weak cladding.

Failure modeDetectionRoot causePrevention
Delamination during bending90° bend test, visualElectroplating instead of claddingSpecify metallurgical cladding in RFQ
Peel strength < specPeel test per ASTM B566Insufficient cladding ratio or weak bondAudit cladding process, require ≥60 MPa
Interface voidsCross-section microscopeDirty raw material or poor cleaningVerify cleaning step in process audit
Resistance rise after TCThermal cycling + resistanceDiffusion barrier failureRequest diffusion barrier alloy if needed

Mechanical failures

Failures during stamping, bending, winding, or vibration. Often related to temper or edge condition.

Failure modeDetectionRoot causePrevention
Cracking at bend radiusBend test per applicationTemper too hardSpecify softer temper or annealed condition
Burr formation in stampingVisual + micrometerSlitting tool wear or wrong edgeSpecify edge condition, audit tooling
Springback in formingDimensional check post-formYield strength too highSpecify yield strength range, not just temper
Fatigue in vibrationVibration test per ISO 16750Surface defects or inclusionsRequest surface inspection report

Electrical and surface failures

Failures in conductivity, solderability, contact resistance. Often related to coating or surface contamination.

Failure modeDetectionRoot causePrevention
Conductivity below specResistance bridgeCladding ratio below specVerify % IACS on every lot cert
Poor solderabilityWetting balance testCoating oxidized or too thinSpecify coating thickness + shelf life
Contact resistance highmΩ meter at connectionSurface contamination or oxideRequest cleaning + protective packaging
Corrosion in damp heatDH1000 visual + resistanceCladding too thin at edgesSpecify min cladding at narrowest point

PV ribbon specific failures

Failures specific to PV ribbon in module manufacturing. These cause stringer downtime and module reliability issues.

Failure modeDetectionRoot causePrevention
Stringer feeding instabilityStringer yield logCamber or spool tension out of specSpecify camber ≤1 mm/m, audit winding
Cell cracks after solderingEL imagingRibbon yield strength too highSpecify yield strength ≤80 MPa for thin cells
Low peel strengthPeel test per IEC 61215Coating wrong alloy or low tempMatch coating to stringer temperature
Hot spot in moduleIR thermographyResistance variation across ribbonSpecify resistance Cpk ≥1.33

Last updated: 2026-06 | This document is a general reference; final specifications are subject to mutually confirmed RFQ documentation.

Contact Raytron Now - Let Every Meter of Material Create Higher Value for You

Raytron focuses on copper-aluminum composite PV ribbon and busbar ribbon, plus CCA, CCS and NCC clad conductors with custom specifications, sample support and production quotations.

13
Precision Rolling Lines

Rolling, slitting and dimensional control

15,000
Tons Annual Capacity

Supports samples, pilot lots and ongoing supply

28
Patents

Clad conductor, rolling and related processes

200 kg
MOQ

Suitable for engineering samples and trial orders

24h
RFQ Reply Within

Our team will respond to your inquiry within 24 hours.

ISO9001
Certified

Quality system and lot traceability support

RFQ Request Quote Response within 24h WhatsApp
Request Quote WhatsApp