Automotive Cable Requirements for Conductor RFQs

Include the applicable cable specification and edition, conductor construction, temperature class and terminal system. Identify the material tests and finished-cable tests needed for the vehicle program.

On this page

Separate conductor and finished-cable requirements

Identify the cable specification and edition used by the vehicle program, including any customer-specific requirements. The cable manufacturer integrates the conductor, insulation and terminal system; a bare-material page does not establish finished-cable approval.

RFQ and document checklist

Scroll horizontally to read all columns. Keep the conditions and units with each value.

Item Information or evidence
Program requirements Applicable cable/customer specification, edition, vehicle market and approval owner
Conductor Material permission, wire/strand construction, dimensions and resistance at stated temperature
Cable construction Insulation system, finished dimensions, thermal class and manufacturing route
Terminations Terminal/tool combination, stripping/crimp settings and mechanical/electrical acceptance
Validation records Defined specimens, methods, conditions, results and scope of program approval

Review the actual document scope and test conditions against the purchase requirements. A declaration, a test report and a management-system certificate serve different purposes.