Rolling, slitting and dimensional control
Dataset Summary
CCA Conductivity Table
Typical conductivity reference ranges for copper clad aluminum conductors used in RFQ screening and application validation.
Download CSVData Table
| Material | Typical Conductivity | Best-Fit Use | Validation Note |
|---|---|---|---|
| CCA 10A | Approx. 62% IACS | General lightweight conductors | Confirm resistance and termination design |
| CCA 15A | Approx. 65% IACS | Cable and selected winding projects | Validate thermal rise and bend behavior |
| CCA 20A | Approx. 68-70% IACS | Higher conductivity CCA designs | Confirm copper ratio, cost and drawing tolerance |
How to Use This Data
- Use the table to shortlist CCA grades before requesting samples.
- Confirm measured resistance, termination method and thermal rise before approval.
Assumptions and Limitations
- Values are RFQ screening references, not a substitute for measured lot data.
- Final resistance depends on conductor geometry, copper ratio, temper and operating temperature.